MiniMed 780G System

MiniMed™ 780G System from Medtronic

Orders are now being accepted for the new MiniMed™ 780G System. 

The MiniMed™ 780G system has "meal detection technology" that provides automatic adjustments and corrections to sugar levels every 5 minutes. Meal detection technology helps cover for underestimated carb counts or an occasional missed meal bolus. The MiniMed 780G insulin pump pairs with the new Guardian 4 sensor. The new system also allows for targets as low as 100 mg/dL.

For complete information, visit MiniMed 780G System

Activity Settings:
Yes
Automatic Correction Boluses:
Yes
Closed Loop Functionality:
Yes
Automatic Insulin Adjustments:
Yes
Calibration Not Required:
Yes
Compatible CGM:
Yes, compatible with both the Guardian 4 Sensor and Guardian 3 Sensor 
Waterproof:
At the time of manufacture and when the reservoir and tubing are properly inserted, the pump is waterproof. It is protected against the effects of being underwater to a depth of up to 12 feet (3.6 meters) for up to 24 hours. This is classified as IPX8 rating. See user guide for more details. The sensor and transmitter are water-resistant at 8 feet (2.4 meters) for up to 30 minutes. CGM readings may not be transmitted from the CGM to the pump while in water. The pump is not intended for submersion in water and is expected to be removed prior to swimming or bathing
Medicare Covered:
Yes
Remote Software Update Capability:
Yes
Multiple Languages:
Yes. Spanish, simplified Chinese, English
Food Database:
No
Additional Features:
  • MiniMed Mobile app allows patients to easily track sugar levels and get notified on their phone or Apple Watch if they are going high or low.   It also allows automatic uploads into CareLink™ software.
  • CareLink™ Connect app allows care partners to download an app to stay in the know
  • CareLink™ software consists of CareLink™ Personal software which converts data from the pump and CGM into easy to understand insights about sugar level and CareLink™ system which healthcare providers access data and reports through. 
  • The system can be used with Medtronic Extended infusion set
 

Size Weight:
Weight <106 grams The pump dimensions in inches are no greater than 3.81 length x 2.18 width x 1.01 depth. The pump dimensions in centimeters are no greater than 9.68 length x 5.36 width x 2.49 depth.
Approved For Ages:
Indicated for persons ages 7 and above
Tubeless:
No
Battery:
AA battery - for best results use a new lithium battery. The pump also accepts an AA alkaline or a fully charged AA rechargeable battery.
Reservoir Capacity:
300 units
Infusion Set:
Compatible with all Medtronic infusion sets including the Extended Infusion set which lasts up to 7 days
Basal Range:

0 - 35 units per hour (Basal increments are:  0.025 U for 0.025-0.975 U/hr; 0.05 U for 1.00-9.95 U/hr; 0.1 U for 10.0 U/hr or more)

Bolus Range:
0 to 25 units (Bolus increment can be set to 0.1 units, 0.05 units, or 0.025 units)
Transmitter Range:
1.8 meters or 6 feet between pump and transmitter.

Guardian™ 4 sensor and transmitter or Guardian™ Sensor 3 and transmitter, MiniMed™ Mobile app, CareLink™ Connect app, Accu-Check® Guide Link blood glucose meter, CareLink™ Software

Important Safety Information:  The MiniMed™ 780G system is intended for the continuous delivery of basal insulin at selectable rates, and the administration of insulin boluses at selectable amounts, for the management of type 1 diabetes mellitus in persons seven years of age and older requiring insulin as well as for the continuous monitoring and trending of glucose levels in the fluid under the skin. The MiniMed™ 780G System includes SmartGuard™ technology, which can be programmed to automatically adjust insulin delivery based on the continuous glucose monitoring (CGM) sensor glucose values and can suspend delivery of insulin when the SG value falls below or is predicted to fall below predefined threshold values.

The Medtronic MiniMed™ 780G System consists of the following devices:  MiniMed™ 780G Insulin Pump, the Guardian™ 4 Transmitter, the Guardian™ 4 Sensor, One-press serter, the Accu-Chek™Guide Link blood glucose meter, and the Accu-Chek™Guide Test Strips. . The system requires a prescription from a healthcare professional.

The Guardian™ 4 Sensor is intended for use with the MiniMed™ 780G system and the Guardian 4 transmitter to monitor glucose levels for the management of diabetes. The sensor is intended for single use and requires a prescription. The Guardian™ (4) sensor is indicated for up to seven days of continuous use.

The Guardian™ 4 sensor is not intended to be used directly to make therapy adjustments while the MiniMed™ 780G is operating in Manual Mode. All therapy adjustments in manual mode should be based on measurements obtained using a blood glucose meter and not on values provided by the Guardian™ 4 sensor. The Guardian™ 4 sensor has been studied and is approved for use in patients ages 7 years and older and in the arm insertion site only. Do not use the Guardian™ 4 sensor in the abdomen or other body sites including the buttocks, due to unknown or different performance that could result in hypoglycemia or hyperglycemia.

WARNING: Do not use the SmartGuard™ feature for people who require less than 8 units or more than 250 units of total daily insulin per day. A total daily dose of at least 8 units, but no more than 250 units, is required to operate in the SmartGuard™ feature.

WARNING: Do not use the MiniMed™ 780G system until appropriate training has been received from a healthcare professional. Training is essential to ensure the safe use of the MiniMed™ 780G system.

WARNING: Do not use SG values to make treatment decisions, including delivering a bolus, while the pump is in Manual Mode. When the SmartGuard™ feature is active and you are no longer in Manual Mode, the pump uses an SG value, when available, to calculate a bolus amount. However, if your symptoms do not match the SG value, use a BG meter to confirm the SG value. Failure to confirm glucose levels when your symptoms do not match the SG value can result in the infusion of too much or too little insulin, which may cause hypoglycemia or hyperglycemia.

Pump therapy is not recommended for people whose vision or hearing does not allow for the recognition of pump signals, alerts, or alarms. The safety of the MiniMed™ 780G system has not been studied in pregnant women, persons with type 2 diabetes, or in persons using other anti-hyperglycemic therapies that do not include insulin. For complete details of the system, including product and important safety information such as indications, contraindications, warnings and precautions associated with the system and its components, please consult https://www.medtronicdiabetes.com/important-safety-information#minimed-780g and the appropriate user guide at https://www.medtronicdiabetes.com/download-library


    The Danatech Digest

    Join 18,000+ professionals who get our latest diabetes technology updates

        

    DISCLAIMERS:

    This site and its services do not constitute the practice of medical advice, diagnosis or treatment. Always talk to your diabetes care and education specialist or health care provider for diagnosis and treatment, including your specific medical needs. If you have or suspect that you have a medical problem or condition, please contact a qualified health care professional immediately. To find a diabetes care and education specialist near you, visit the ADCES finder tool.

    ADCES and danatech curate product specifics and periodically review them for accuracy and relevance. As a result, the information may or may not be the most recent. We recommend visiting the manufacturer's website for the latest details if you have any questions.


    Our Sponsors