Search

MiniMed™ 770G System

MiniMedTM 770G System from Medtronic 

The MiniMedTM 770G system automatically adjusts basal insulin every 5 minutes using real-time sensor glucose readings. The system connects directly to a smartphone, allowing the patient and care partners to view both glucose trends and insulin delivery on the go. FDA approved for ages 2 and up.

For complete information, visit Medtronic

Activity Settings:
Yes. Temp target option raises target glucose to 150mg/dL for duration 30 minutes to 12 hours
Automatic Correction Boluses:
No
Closed Loop Functionality:
Yes
Automatic Insulin Adjustments:
Yes.
Calibration Not Required:
No. The first calibration is due within 2 hours after connecting a new sensor. The next calibration is due within 6 hours after the first calibration and subsequent calibrations are due every 12 hours and as needed.
Compatible CGM:

Medtronic Guardian Sensor 3 with Guardian Link 3 Transmitter

Waterproof:

Yes. The MiniMedTM 770G pump is protected against the effects of being underwater to a depth of 12 feet for 24 hours. But the sensor and transmitter are water-resistant at 8 feet for up to 30 minutes. CGM readings may not be transmitted from the CGM to the pump while in water.

Medicare Covered:
Yes
Remote Software Update Capability:
No. Will be available when 780 approved by FDA
Multiple Languages:
Yes
Bolus Management Smartphone:
No. Remote bolus not available from AccuChek Guide Link glucometer. MiniMed Mobile app available that allows remote viewing of insulin pump and CGM data and ability to share with Care Partner
Food Database:
No
Additional Features:
  • The MiniMed 770G system with SmartGuard Auto Mode automatically adjusts basal insulin delivery every 5 minutes. By constantly adapting to real-time glucose needs and targeting a sensor glucose of 120 mg/dL, SmartGuard technology* can help optimize patients’ time in range (70-180 mg/dL).
  • When used with the Guardian Sensor 3 in Manual Mode, the MiniMed 770G system enables different levels of automation. Specifically, the SmartGuard SUSPEND BEFORE LOW feature can help reduce hypoglycemic excursions by stopping insulin delivery up to 30 minutes before reaching the preset low sensor glucose limit.
  • The MiniMed 770G system works with the AccuChek Guide Link glucometer. Remote bolus is not available.
  • Carelink Connect Care Partner app available for those using MiniMed Mobile app. See Medtronic website to check compatibility. Full hybrid closed loop Auto Mode features available without smartphone.

** Additionally, insulin delivery can automatically resume once the sensor glucose levels recover.

Size Weight:
Pump: 3.78 in x 2.11 in x 0.96 in (L x W x D), approximately 3 ounces (without battery). 1.4 in x 1.12 in x 0.37 in (L x W x D)
Approved For Ages:
Indicated for persons ages 2 years and up
Tubeless:
No
Battery:
Pump: One AA battery. Charger: One AAA battery
Reservoir Capacity:
Up to 300 units for use with Humalog or Novolog rapid-acting insulin
Infusion Set:
Works with all MiniMedTM Infusion Sets listed below under Product Pairing.
Basal Range:

When in Auto Mode: Basal rates self-adjust every 5 minutes in 0.025-unit increments .When in Manual Mode: Basal rates: 0-35 units/hour; Basal rate increments 0.025 units/hour when less than 1.0 units/hour. Basal profiles: 8 with up to 48 rate changes available per day.

Bolus Range:
0.025 units - 25 units in 0.025-unit increments (adjustable)


The Danatech Digest

Join 18,000+ professionals who get our latest diabetes technology updates

    

DISCLAIMERS:

This site and its services do not constitute the practice of medical advice, diagnosis or treatment. Always talk to your diabetes care and education specialist or health care provider for diagnosis and treatment, including your specific medical needs. If you have or suspect that you have a medical problem or condition, please contact a qualified health care professional immediately. To find a diabetes care and education specialist near you, visit the ADCES finder tool.